4 General Requirements
4.4.2 Rear outlet flue system
(100 mm outside diameter)
The rear outlet horizontal flue system (Art. No. 303 817)
is suitable for installations up to 600 mm wall thickness.
Fig. 4.3: Art.-No. 303 817
4.4.3 Extended top outlet flue system
(125 mm outside diameter)
A top outlet horizontal flue system of 125 mm outside
diameter is also available (Art. No. 303 609) and can be
used to achieve flue lengths of up to 12.9 m for 24 kW;
10 m for 28 kW.
Both 45° and 90° bends and elbows are also available to
increase siting flexibility.
A vertical 125 mm concentric flue system is also availa-
ble (Art. No. 303 600).
Refer to flue system installation instructions for full
details.
Fig. 4.4: Art.-No. 303 609
70
1103
70
15
800
Instructions for Installation and Servicing turboMAX pro R38
4.4.1 Top outlet flue system
(100 mm outside diameter)
The top outlet horizontal flue system (Art. No. 303 807)
is suitable for installations up to 720 mm measured from
the centre of the boiler flue outlet to the outside face of
the wall. Flue extensions are available to extend this
length up to 4.5 m for 24 kW and 3.2 m for 28 kW.
Both 90° bends and 45° elbows are also available to
increase siting flexibility.
A vertical flue system is also available
(Art. No. 303 800).Refer to flue system installation
instructions for full details.
Fig. 4.1: Art.-No. 303 807
A vertical flue system is also available
(Art. No. 303 800).
Refer to flue system installation instructions for full
details.
Fig. 4.2: Art.-No. 303 800