Operating Manual geoTHERM exclusive VWS 0020071929_0014
5.2 Setting menus and parameters
Setting to date Modified setting
Holiday programming
6
for cpl. System
Period of
time
1 >06.01.08 08.01.08
2 14.01.08 30.01.08
Room Temp. setpoint 12°C
>Set start day
Select menu:
Turn the dial: Select
menu e.g. from menu 6 to
7.
Basic data
7
Date >21.04.08
Day of
week
Mo
Time 09:35
>Set day
Basic data
7
Date >21.04.08
Day of
week
Mo
Time 09:35
>Set day
Select parameter:
Turn the dial: select the
parameter to be modified
e.g. from line 1 day to line
2 weekday (in this
example continue to turn
3 snap-in points).
Basic data
7
Date 21.04.08
Day of
week
>Mon
Time 09:35
>Set weekday
Basic data
7
Date 21.04.08
Day of
week
>Mon
Time 09:35
>Set weekday
Modify parameter weekday
from Monday to Tuesday:
Push the dial:
Select parameter:
Turn the dial:
Modify parameter,
Push the dial:
Accept modification.
Basic data
7
Date 21.04.08
Day of
week
>Tues
Time 09:35
>Set weekday
Fig. 5.2 Setting menus and parameters
5.3 Controller description
The heating engineer will have set all the operating pa-
rameters to preset values during commissioning, so that
the heat pump can function optimally. However you can
individually set and adapt the operating modes and
functions afterwards.
5.3.1 Possible system circuits
The controller can control the following system circuits:
– a heating circuit,
an indirectly heated hot water storage tank,
a hot water circulation pump,
– a buffer circuit.
In order to extend the system a buffer circuit can be
used to connect up to six additional mixer circuit mod-
ules VR 60 (accessories) each with two mixer circuits.
The controller on the operating panel of the heat pump
is used to programme the mixer circuits. In order to op-
erate under comfortable conditions you can connect the
remote control units VR 90 for the first eight heating
circuits.
5 Operation