11Operating and installation manual for VR 61 mixer module
Mark the two fixing points at a suitable position in
accordance with the fixing openings (1).
Drill two holes for the suitable plugs and screw the
casing
securely in position.
The electrical installation is carried out as
described in Chapter 6.
Insert the casing cover back into the hinges and
hinge the casing cover back up into position.
Screw the casingcover in position in accordance with
Fig. 5.1.
5.3 Assembling VR 10 standard sensor
The VR 10 standard sensor is so designed that it can be
used as a cylinder sensor, (e.g. as an immersion sensor
in a cylinder sensor tube) or as a flow sensor
(e.g. in a hydraulic switch).
The fixing tape enclosed can also be used to fix the
VR 10 as a contact sensor onto a heating pipe. We
recommend that the pipe with the sensor is insulated
to ensure optimum temperature measurements.
Fig. 5.3 Standard sensor VR 10 as contact sensor
6 Electrical installation
The electrical connection must be done by a suitably
qualified heating engineer who is responsible for
complying with the existing standards and guidelines.
e
Danger!
Connections carrying voltage!
When working in the open mixer module
VR 61 and in the control cabinet of the heating
equipment there is a danger to life by electric
shock.
Before working on the mixer module VR 61 and
in the control cabinet of the heating equipment
turn off the power supply and secure against
re-engagement.
The LED (green) on the PCB of the mixer
module VR 61 must not light up.
If the casing of the mixer module VR 61 is closed , open
it as described under Chapter 5.2.
6.1 Connecting VR 61 mixer module
The mains input is provided by the user up
to the mixer module VR 61.
The eBUS connection to the mixer module VR 61 can be
branched off at any point in the eBUS system
(see Fig. 6.1).
Wire up the mixer module VR 61 as shown in Fig. 6.2.
h
Note!
The cables for the 230 V mains connection and
for e-BUS connection are not included in the
supply.
The storage tank sensor 1 (SP1, accessories
VR 10) is connected to the wiring harness of
the heating equipment (see the documents
which also apply, installation instructions
heating equipment). This also applies if the
storage tank charging pump is connected
directlyinto the mixer module VR 61.
If a hydraulic switch is fitted the feed sensor 1
(VF1, accessories VR 10) is mounted in the feed
behind or within the hydraulic switch. The
connection is carried out via the edge
connector X8 (included in the controller
VRC 430 or VRC 430f) in the control cabinet
of the heating equipment (see Fig. 6.3).
Assembly 5
Electrical installation6