Vaillant ecoMAX 613/2 E Service Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
10
2 Boiler Specification
3 General requirements
Instructions for installation and servicing ecoMAX10
2.7 Identification plate
The identification plate of the Vaillant ecoMAX is sup-
plied ready–attached to the bottom of the unit.
Fig. 2.8 Identification plate (example)
3 General requirements
3.1 Preliminary remarks
This appliance should only be installed in conjunction with
a Vaillant flue system. Install the flue system as detailed
in the separate flue installation instructions supplied
with this boiler.
3.2 Related documents
The installation of the boiler must be in accordance with
the relevant requirements of Gas Safety (Installation
and Use) Regulations 1998, Health and Safety Document
No. 635 (The Electricity at Work Regulations 1989),
BS7671 (IEE Wiring Regulations) and the Water Supply
(Water Fitting) Regulations 1999, or The Water Bylaws
2000 (Scotland). It should also be in accordance with the
relevant requirements of the Local Authority, Building
Regulations, including amendments to the Approved
Documents Part L and J 2002, The Building Regulations
(Scotland). The Building Regulations (Northern Ireland)
and the relevant recommendations of the following
British Standards:
BS 5440: Flues and ventilation of gas fired boilers not
exceeding 70 kW net:
– Part 1: Flues
– Part 2: Ventilation
BS 5449: Specification for forced circulation hot water
for domestic premises.
BS 5546: Specification for gas hot water supplies for
domestic premises.
BS 6700: Services supplying water for domestic use
within buildings and their curtilages.
BS 6798: Specification for installation of gas fired boi-
lers not exceeding 60 kW input.
BS 6891: Specification for installation of low pressure
gas pipework up to 28 mm (R1) in domestic premises
(2nd family gas).
BS 7593: Treatment of water in domestic hot water cen-
tral heating systems.
Institute of Gas Engineers Publication IGE/UP/7/1998:
”Guide for gas installations in timber framed housing”
Important:
The appliance must be installed and serviced by
a Competent Person as stated in the Gas Safety
(Installation and Use) Regulations 1998. In IE,
the installation must be in accordance with the
current edition of I.S.813 ‘Domestic Gas
Instal–lations’, the current Building Regulations
and reference should be made to the current
ETCI rules for electrical installation.
Important:
When tightening or loosening screwed connec-
tions always use suitable open–ended spanners
(not pipe wrench, or extensions, etc.).
Incorrect use and/or unsuitable tools can lead to
damage being caused (e.g. gas or water leakage)!
83 41 77_12 GB04.04.qxd 22.09.2004 12:34 Uhr Seite 10