Vaillant VRC 430f Installation Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
13Operating Manual VRC 430 0020042468_02
08:00 12:00
15 °
20 °
25 °
Room temperature
Time
Period
08:00 12:00
15 °
20 °
25 °
Time
Period
23
4
1
Set back
temperature
Room temperature
Fig. 4.11 Period of validity of changed set target value
(here: Target room temperature
The top diagram in Fig. 4.11 shows a programmed period
(see Chapter 4.7.1) with the associated room set tem-
perature (21 °C).
The lower diagram, the bar marked (1), shows that the
target room target value is changed (20 °C). This target
value is maintained until the start of the new period.
From here (2) the control system uses the room set tar-
get value of the time window (21 °C).
At (3) the room set target value is set (17 °C).
The control system applies this value until the end of
this period (4).
After this period, the control system reverts to the set-
back temperature (15 °C).
h
Note!
The same applies to the hot water target value.
4.5 Operator level, Expert technician level
The VRC 430 controller has two operating levels. Each
level contains several display screens where the param-
eters can be displayed, set or changed.
Operating level for the operator
This is used to display, set/change the basic parame-
ters. The parameters can be set/changed by an un-
skilled operator and during normal operation.
Operating level for the expert technician
This is used to display and set/change specific param-
eters and is restricted to the expert technician.
4.6 Screens in the operating level for the
operator
The screens in the operation level for operators are ar-
ranged the same sequence as shown in table 4.4. below.
This table shows the parameters which can be set and
changed.
Examples of this can be seen in chapter 4.7 below.
To access the first "basic data" screen at operator level
from the simplified basic view:
Click one or both dials.
This will take you to the basic display.
Turn the left-hand dial clockwise one or two posi-
tions (clicks).
Day of week
We
12 : 00
> Set day of week
21 . 06 . 06
Basic data
1
Date
Time
Summer/winter time changeover
Auto
Fig. 4.12 "Basic data" screen (Example: selecting the day of
the week)
Turn the left-hand dial again to jump from one screen to
the next.
If additional components are installed and controlled by
the VRC 430, the display screens listed in table 4.4 will
contain the additional screens as required, e.g. 3 or
6.
Operation 4
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 39 40

Comments to this Manuals

No comments