Vaillant aquaPLUS VUI 362-7 Service Manual Page 32

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 31
8 Functional checks (Commissioning Part III)
Instructions for installation and servicing aquaPLUS VUI 362-732
8 Functional checks (Commissioning
Part III)
8.1 Functional checks
Once the unit has been installed and the gas supply has
been checked, operate the system to ensure that it is
working correctly.
Operate the system, following the operating
instructions supplied with the boiler.
Check the system for water leaks and escaping gas.
Check that the flue has been correctly installed,
according to the fitting instructions supplied with the
flue assembly.
Check the burner for correct ignition and flame
picture.
Check the hot water system for correct operation.
Check the heating system for correct operation.
Fig. 8.1: Test for correct functioning
I
0
This appliance is fitted with a display unit that uses
symbols to show the current operating status of the
boiler. Additionally to this the status of the boiler can be
checked using the Status Mode.
8.2 Hot-water supply
Activate the system.
Fully open one of the hot water taps in the system.
Press the ”i“ key.
Status code “S.14” appears on the display to indicate
that the hot-water supply is functioning correctly.
Fig. 8.2: Display indication while hot water is being supplied
8.3 Power store filling mode
Note: The power store is delivered turned off and
must be turned on during commissioning.
Activate the system.
Ensure that the hot water thermostat is set to the
required heat level.
Press the ”i“ key.
Status code “S.24” appears on the display if the tank is
being recharged.
Fig. 8.3: Display indication during power store filling mode
834702_33GB_012005.qxd 09.03.2005 16:26 Uhr Seite 32
Page view 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 59 60

Comments to this Manuals

No comments