23Instructions for installation and servicing ecoTEC
Danger!
This appliance must be earthed.
Danger!
Mains connection terminals L and N remain live
even when the boiler on/off control is switched
off.
Note
Do not connect any power voltage to the con-
nections 7-8-9 or BUS (+,-).
Note
Ensure that all cords pass through the cable
clamps in the rear of the control box and are
securely fixed. Ensure that the power supply is
connected such that the current carrying con-
ductors become taut before the earth conductor
should the supply cord slip from the cable clamp.
4.13.2 Connection to the main supply
Remove the front case and lower the control panel.
Fig. 4.13 Opening the electronics box
Unclip the bottom of the terminal box cover and hinge
back to reveal the connection plugs.
Feed the power supply flex into the appliance and the
control panel through the cable clamps provided and
tighten.
-+789 LN 345
-+789 LN 345
Fig. 4.14 Wiring system
Connect the flex to the L, N and earth plug to the ter-
minal block.
Green/yellow (earth) wire – boiler terminal Earth sign
Blue (neutral) wire – boiler terminal N
Brown (live) wire – boiler terminal L
Note
Do not connect any power voltage to the con-
nections 7-8-9 or BUS (+,-).
Note
Ensure that the wires are securely fixed in the
terminal block.
Refit the terminal box cover by pushing into place until
it clips back into position.
Raise the control panel.
Boiler installation sequence 4