Installation and maintenance instructions ecoTEC plus 937 0020031552_06 27
2
1
3
6
2
4
5
1
Fig. 5.6 Gas connection
Proceed as follows for gas connection:
Remove the gas connection pipe elbow (2) and gas
isolator valve (1) from the packaging.
Push the union nut (3) and the olive (4) onto the gas
pipe which protrudes from the combi boiler.
Push the gas isolator valve (1) onto the gas pipe
which protrudes from the combi boiler up to the stop.
Pull the union nut (3) with the olive (4) towards the
gas isolator valve. Tighten the union nut hand tight.
Push the union nut (6) and the olive (5) onto the gas
connection pipe elbow (2).
Push the gas connection pipe elbow (2) into the gas
isolator valve (1) up to the stop.
Pull the union nut (6) with the olive (5) towards the
gas isolator valve. Tighten the union nut hand tight.
The diameter of the pre-formed copper pipe (2) is
22 mm. Connect this pipe to a gas supply pipe having
a diameter of not less than 22 mm.
i
The gas supply pipework must be of sufficient
size so that, at maximum output, a gas pres-
sure of 20 mbar is available at the input to
the combi boiler.
Tighten all connections.
Purge the gas pipe before commissioning.
Check the gas connection for leaks using leak-detect-
ing spray.
>
>
>
>
>
>
>
>
>
>
>
5.12 Connecting the hot and cold water
a
Danger!
Risk of scalding and damage due to leaking
water.
Possible leaks in water pipes.
Make sure there is no tension in the supply
lines when they are installed.
b
Caution!
Risk of damage to gas shut-off valves
caused by heat transfer.
If the final connections are soldered, the heat
transferred during the process may damage
the gas shut-off valves.
Use extra care when soldering.
b
Caution!
Risk of damage to the appliance.
Residue in the pipes, such as welding beads,
scale, hemp, putty, rust and coarse dirt, may
be deposited in the appliance and cause mal-
functions.
Flush the cold water inlet pipe thoroughly
before connecting the appliance in order to
remove any residue that may be there.
1
2
3
4
5
6
7
Fig. 5.7 Installing the cold water and hot water connections
Remove the two copper tails (5, 6) for water connec-
tion, the cold water isolating valve (2) and the union
nut (4), olive (3) and fibre seals (1, 7) from the pack-
aging.
Insert the fibre seal (1) and screw the cold water iso-
lating valve (2) to the cold water connection of the
shift load storage tank.
>
>
>
>
>
Sequence of operations during installation 5