Boiler Installation Sequence 5
Instructions for Installation and Servicing turboMAX pro R3 19
Fig. 5.14
Thermostatic radiator valves
The boiler has a built in automatic bypass valve making
it ideal for use in systems with thermostatic radiator val-
ves (no separate system bypass is required).
For optimum fuel economy it is recommended that
where TRV’s are used they are used in conjunction with
a programmable room thermostat or separate timer and
room thermostat to ensure complete boiler shut down
when the heating demand is satisfied. (The radiator in
the room containing the room thermostat should not be
fitted with a TRV).
Frost protection
The boiler has an integral frost thermostat which is desi-
gned for protection of the boiler.To protect remote or
exposed parts of the heating system or property additio-
nal frost protection measures must be taken such as the
installation of an external frost thermostat. This frost
thermostat should be connected across the boiler termi-
nals 3 and 4, in parallel with any external heating con-
trols. External frost protection cannot be used when
plug in timers have been fitted.
Circulating pump
The boiler incorporates a built in circulating pump that
is fully prewired (no additional wiring is necessary). The
pump incorporates an automatic overrun period after
the boiler switches off.
Anti-cycling economiser’ control
The boiler incorporates a built in anti-cycling control to
ensure that energy wasteful short cycling of the boiler
cannot occur. This control prevents the boiler from re-
igniting for a preset period of 5 minutes after central
heating operation (the hot water operation is unaffected
by this control and hot water can be drawn at any time).
Note!
To temporarily override the anti-cycling control
turn the main boiler on/off switch to the off
position „0“ and then back to the on position
„I“ after a few seconds.
3
987
MAINS
SUPPLY
230 V
50 Hz
L
L
LN
N
N
N
20 VDCDO NOT USE IN UK!
3 A FUSE
SWITCH
CONTACTS
ROOM
THERMOSTAT
CLOCK
4
5
Automatic pump spin control (APS)
The boiler incorporates a built in control which will spin
the built in circulating pump and operate the diverter
valve (turboMAX only) once in a 24 hour period. This
control helps to prevent seizure when the boiler is not
operated for a period of time. This control is not active
when the power supply to the appliance is turned off.
833792_41GB_012005.qxd 09.03.2005 16:47 Uhr Seite 19