9.3.4 Making Holes for the Pipes
• Case A: laying the rear piping.
In the event of laying the rear piping, a suitable hole
must be made (see Figure 9.1).
• Drill a hole in accordance with the diameter
indicated in Figure 9.1, slightly descending to the
outside.
Fig. 9.1 Dimensions of the hole for the piping.
• Case B: laying the side or bottom piping.
In this case holes do not have to made on the wall
since the indoor unit body has windows which can be
opened to admit the pipes: choose the most adequate
one for the desired outlet position (see Figure 9.7).
Carefully break the chosen window on the lid using pliers.
Fig. 9.7 Windows for the installation of the pipes.
Legend
1 Lid for right piping
2 Lid for indoor piping
3 Securing with adhesive tape
4 Lid for left piping
9.3.5 Laying the Pipes
• If installing the rear piping:
Place the lid supplied for the hole in the piping and
insert the coolant pipes with the condensed water
pipe through the hole.
Seal the hole properly after installing the pipes.
• Carefully bend the installation pipe in the right
direction.
Warning!
Danger of breakdowns or malfunction. Danger of
wear in the coolant pipes.
Bend the pipe carefully to prevent choking or
breaks.
• Cut the pipes, leaving enough extra piping hanging
over to enable the unit to be hooked up at the indoor
unit joins.
• Insert the nut in the coolant pipe and carry out
the flaring.
• Carefully remove the insulation of the flared
connections in the indoor unit.
• Hang the indoor unit on the top edge of the
mounting plate.
• Tilt the lower part of the indoor unit forwards and
insert an auxiliary tool (e.g. a piece of wood) between
the mounting plate and the unit (see Figure 9.8).
Fig. 9.8 Assembling the indoor unit.
• Connect the coolant pipes and the condensed water
hose to the corresponding pipes and installation drain.
• Insulate the coolant piping correctly and separately. To
do so, cover any possible cuts with masking tape or
insulate any bare coolant piping with the
corresponding insulation material used for cooling.