Split Type Installation Manual16
Split Type Installation Manual 17EN
Fig. 11.2 Wiring indoor unit, model V 7-025 NW and V 7-035 NW.
Legend
1 Strip for the indoor unit
2 Strip for the outdoor unit
• Check that the cables are properly fixed and
connected, position the wiring cover and mount the
outside body.
• Models V 7-025 NW and V 7-035 NW are equipped with
a plug in the indoor unit.
11.4 Electric Connection of the Outdoor Unit
Warning!
Danger of breakdowns or malfunction. If the fuse
on the PC board is blown please change it
with type T. 25A/250V.
• Remove the protective covering in front of the
electrical connections in the outdoor unit.
• Loosen the screws in the bushing block and fully insert
the cable terminals of the power supply line in the
bushing block and tighten the screws.
Warning!
Danger of malfunction and breakdowns resulting
from water penetration.
Mount the power cable below the bushings using
a cable loop in order to avoid water penetration.
Warning!
Danger of malfunction and breakdowns resulting
from short-circuits.
Insulate the unused cable wires using masking
tape and ensure that they cannot come into
contact with low voltage parts.
• Secure the cable installed with the outdoor unit's
contracting device.
• Check that the cables are correctly secured and
connected.
• Mount the protective wiring cover.