Vaillant climaVAIR V 7-035NW Installation Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
Split Type Installation Manual16
Split Type Installation Manual 17EN
Warning!
Danger of breakdowns or malfunction.
Size the electric wiring with sufficient capacity.
Warning!
Danger of breakdowns or malfunction.
Compliance with the Standard EN 61000-3-11:
Check that the nominal power of the main phase
current connection is > 100.
Warning!
Danger of breakdowns or malfunction.
Ensure that the supplied power voltage is in the
range of 90% to 110% of the rated voltage.
Warning!
Install the unit in such a way that the electric
plug is easily accessible. Thus, if required, the
unit can be quickly disconnected.
11.2 Remark with regard to Directive 89/336/EEC
In order to prevent electromagnetic interference during
the start up of the compressor (technical process), the
following installation conditions must be adhered to.
• Make the air conditioning unit power supply
connection at the main power distribution. Carry out
the distribution with low impedance. Normally the
required impedance is reached at a
32 A fusing point.
• Check that no other equipment is connected to this
power supply line.
Note!
For more detailed information on the electric
installation, please consult the Technical
Connection Conditions applied by your electricity
supply board.
Note!
In order to obtain more information with regard
to power details of the air conditioner consult
the unit rating plate.
11.3 Electric Connection of the Indoor Unit
Warning!
Danger of breakdowns or malfunction. If the fuse
on the PC board is blown please change it
with type T. 3,15A/250V.
• Disassemble the outdoor body of the indoor unit by
pulling it upwards.
• Remove the wiring cover on the right of the body by
unscrewing it (see Figure 11.1).
Fig. 11.1 Wiring Cover.
• Insert the cable from the outside:
• Using the same hole through which the coolant pipes
are installed (or are going to be installed later) or,
• Using another of the pipe installation windows
provided on the body.
• Pull the electrical cable from the rear of the indoor
unit through the specific hole in the front.
• Connect the line on the terminal strip of the indoor
unit according to the corresponding wiring diagram
(see Figures).
11 Electric Wiring