Loosen screws on the 95 mm diameter
x 55mm wide clamp (6, fig. 21) and
push over the air duct.
Remove screws and sealing washer
on the 95 mm diameter x 25 mm
wide clamp (3, fig. 21) and push onto
the flue elbow on the side to be
connected to the appliance. Ensure
the clamp is clear of the end of the
elbow.
Push the flue elbow into the clamp (2,
fig. 20) connected to the appliance
flue gas duct and tighten the securing
screws lightly.
Ensure that the elbow and air/flue
duct line up and are closely butted
together. Pull the clamp (4, fig. 20)
over the joint between the flue gas
duct and flue elbow. Ensure that the
air/flue duct and terminal are correctly
positioned. Tighten the securing screws
on both clamps.
Note : Excessive tightening of these
screws is not necessary. Ensure that
the air / flue duct and terminal
assembly is not displaced though the
wall. Check that the air duct of the
terminal still projects by 90 mm
through the wall.
Refit the half ring 2, fig. 21. Pull the
95 mm diameter x 25 mm wide
clamp (3, fig. 21) over the joint
between the flue elbow and half rings.
Refit the screws and sealing washer
and tighten lightly.
Pull the 95 mm diameter x 55 mm
wide clamp (6, fig. 21) over the joint
between the flue elbow and air/flue
duct. Tighten the securing screws on
both clamps.
Drill two holes, 3 mm diameter
through both air duct clamps into the
air ducts at the most convenient
positions (5, fig. 21). Take care not to
penetrate the inner flue duct. Screw
the clamps to the air ducts using the
self tapping screws provided.
4.6.2 Vertical Flue
Remove the two half rings (2, fig. 18)
and, if necessary, fit the flue restrictor
ring.
(Note: It will be necessary to remove
both half rings if the flue restrictor ring
is to be fitted. The flue restrictor ring
should be placed on top of flue outlet
directly below the two half rings (see
fig. 18A). One half ring should be
replaced immediately).
Fit the 63 mm diameter x 68 mm wide
flue duct sleeve (2, fig. 22) over the
flue gas duct of the air/flue duct
assembly.
Loosen the screws of the 95 mm
diameter x 55 mm wide clamp (1, fig.
22) and push over the air duct of the
air/flue duct assembly.
Lower the flue assembly until a gap of
about 25 mm exists between the air
duct of the air/flue duct and terminal
assembly and the half rings on the
appliance. The two ducts must not butt
together.
Pull the sleeve (2, fig. 22) down over
the flue connection of the appliance
against the stop. Align the holes in the
sleeve and boiler flue gas connector
and secure with a self tapping screw
(1, fig.23).
Note : The sleeve must not be screwed
to the bottom of the flue gas duct of
the air/flue duct assembly. This duct
must be able to slide in order to
absorb small movements of the roof
structure.
Refit the two half rings. Pull the 95mm
diameter x 55 mm wide clamp down
over the joint between the air/flue duct
assembly and the half rings. Tighten
the clamp screws (1, fig.24).
18
fig. 21
fig. 20
GW 616/0
GW 594/0
fig. 22
GW 558/0
fig. 24
GW 602/0
fig. 23
GW 560/0