17Instructions for installation and servicing ecoTEC 839592_12
Vessel Volume [L]
Initial system pressure (bar) 1.0 1.5
Pressure relief valve setting (bar) 3.0
Total water content of system litres
25 2.7 3.9
50 5.4 7.8
100 10.9 15.6
125 13.6 19.5
150 16.3 23.4
175 19.1 27.3
200 21.8 31.2
225 24.5 35.1
250 27.2 39.0
275 30.0 42.9
300 32.7 46.8
325 35.7 50.7
350 38.1 54.6
375 40.9 58.5
400 43.6 62.4
425 46.3 66.3
450 49.0 70.2
475 51.8 74.1
500 54.5 78.0
For system volumes other than those given
above, multiply the system volume by the
factor across
0.109 0.156
Table 3.7 Sizing of additional expansion vessel
3.11 Pump specifications
3.11.1 Circulating pump
only ecoTEC plus:
The circulating pump is included in the boiler. The residual
pump discharge height depending on the by-pass valve is
shown in Fig. 3.10.1 (ecoTEC plus) and 3.10.2 (ecoTEC plus
637 / 837).
The operating mode of the 2-step pump can be adjusted
below the diagnosis number “d.19”, see section 8.1.2.
400
300
200
100
0
0 200 400 600 800 1000 1200 1600
Lift
[
mbar
]
Volumeflow
[
l/h
]
1800
1400
2. Step1. Step
Fig. 3.10.1 Pump specifications ecoTEC plus
(except ecoTEC 637 and 837)
400
300
200
100
0
0 200 400 600 800 1000 1200 1600
Lift
[
mbar
]
Volumeflow
[
l/h
]
18001400
2. Step1. Step
2000
Fig. 3.10.2 Pump specifications only ecoTEC 637 and 837
only ecoTEC pro:
The circulating pump is included in the boiler. The
ecoTEC pro appliances are fitted with a single-stage
pump. The residual pump discharge height depending on
the by-pass valve is shown in Fig. 3.11.
400
300
200
100
0
0 200 400 600 800 1000 1200 1600
Lift
[
mbar
]
Volumeflow
[
l/h
]
1800
1400
Fig. 3.11 Pump specifications ecoTEC pro
3.11.2 System by-pass
An automatic system by-pass is provided in the boiler.
The boiler is suitable for use in systems with
thermostatic radiator valves and no additional by-pass
is required. The by-pass valve is adjustable, see section
5.3.
3.11.3 Venting
The boiler is fitted with an automatic air vent. Additional
provision should be made to enable the heating system
to be vented during filling and commissioning either by
automatic air vents or manually.
3.12 Condensate trap
The boiler is fitted with a siphonic condensate discharge
(ecoTEC plus) or a condensate trap (ecoTEC pro)
incorporating a water trap of 140 mm.
General requirements 3