9.3.3 Handling the Condensed Water Pipe
Warning!
Danger of breakdowns or malfunction. Danger of
incorrect drainage of the condensed water and
wear of materials due to dripping water.
Take the following points into consideration:
- Ensure that air circulates through the condensed
water pipe in order to guarantee that the water can be
freely released. Otherwise, the condensed water could
leak through the indoor unit body.
- Mount the pipe without bending it in order to avoid
blockage.
- If the water pipe is channelled outdoors, ensure that it
is insulated against freezing.
- If the condensed water pipe is installed in a room, fit
thermal insulation.
- Avoid installing the condensed water pipe with an
ascending bend (see Figure 9.2).
Fig. 9.2 Avoid ascending bends.
- Avoid installing the condensed water pipe with it free
end submerged in water (see Figure 9.3).
Fig. 9.3 Avoiding submerging the end.
- Avoid installing the condensed water pipe with
crimping (see Figure 9.4).
Fig. 9.4 Avoid crimping.
- Install the condensed water pipe in such a way that
the distance of its free end from the floor is at least 5
cm (see Figure 9.5).
Fig. 9.5 Minimum distance from the floor.
Legend
H Minimum distance from the floor: 5 cm
- Install the condensed water pipe in such a way that its
free end is kept away from unpleasant odours to
ensure that they do not penetrate the room (see
Figure 9.6).
Fig. 9.6 Avoids unpleasant odours.
Installation of the indoor unit 9