Split Type Installation Manual14
Split Type Installation Manual 15EN
Fig. 10.1 General diagram of the installation and the minimum
assembly distances.
Legend
1 Indoor Unit
2 Outdoor Unit
3 Pipe for draining the condensed water
A Front separation (minimum 10 cm)
B Top separation in relation to the ceiling (minimum 5 cm)
C Separation fixing wall (minimum 10 cm)
D Height in relation to the floor (minimum 2 m)
E Side separation opposite side connections (minimum 10 cm)
F Rear separation (minimum 10 cm)
G Side separation connections side (minimum 15 cm)
H Front separation (minimum 60 cm)
10.2 Planning the Coolant Return
The coolant circuit contains a special oil to lubricate the
outdoor unit compressor. To assist the return of the oil
to the compressor the following is recommended:
- that the indoor unit is located higher than the outdoor
unit and,
- that the suction pipe (the thickest one) is assembled
with the tilt towards the compressor.
If the outdoor unit is mounted higher than the indoor
unit, the suction pipe must be mounted in a vertical
position. At heights exceeding 7.5 m:
• An additional oil deposit should be installed at each
7.5 m interval to collect the oil and suction it, returning
it to the outdoor unit and
• An elbow can be installed in front of the outdoor unit
to further assist the oil return.
10.3 Connection of the Coolant Pipes
Note!
Installation is easier if the gas suction pipe is
connected up first. The suction pipe is the
thickest one.
• Mount the outdoor unit in the designated site.
• Remove the protection hoods from the coolant joints
in the outdoor unit.
• Carefully bend the installed pipe towards the outdoor
unit.
Warning!
Danger of breakdowns or malfunction. Danger of
wear in the coolant pipes.
Bend the pipe carefully to prevent choking or
breaks.
• Cut the pipes, leaving enough extra piping hanging
over to enable the unit to be hooked up at the outdoor
unit joins.
• Flare the coolant pipe when installed.
• Join the coolant pipes to the corresponding outdoor
unit connection.
• Insulate the coolant piping correctly and separately.
To do so, cover any possible cuts with masking tape or
insulate any bare coolant piping with the
corresponding insulation material used for cooling.