4 Installation Manual auroMATIC 560
ProE-system wiring
C1/C2
C1 C2
KOL1
21
SP1
21
SP2
21
SP3
21
Ertrag
21
KOL2
21
230 V~
PE N L
KOL1-P
PE N L
LEG/BYP
PE N L
LP/UV1
PE N L
EP
21
KOL2-P/Z P
PE N L
3
Fig. 4.4 Fold-up the control panel
Fold the control panel towards the top.
Wire the controller according to the selected hydraulic
plan (see Section 5.1).
Secure all cables with the accompanying cable clamps
(3).
Fold the control panel back down.
Attach the front cover again.
5 Electrical installation
The electrical connection may only be carried out by an
approved specialist company.
Danger!
Risk of fatal electric shock from touching live
connections. Before working on the appliance,
turn off the power supply and secure against
restart.
Caution!
The circuit board can be damaged if short
circuited through the connection leads. For
safety purposes, a max. of 30 mm of insulation
may be removed from the ends of 230 V leads
which will be connected to ProE plugs. If more
insulation is removed, there is a risk of short
circuiting the circuit board.
Caution!
When exchanging the controller in an existing
system, sensor-curve characteristics should be
taken into consideration (see Sec. 11), and the
sensors should be replaced if necessary!
Caution!
An optional electric heating rod (EP) must be
installed with an additional relay or contactor
with a circuit-breaking capacity of at least 16 A.
Never operate an electric heating rod in connec-
tion with the auroMATIC 560 without an addi-
tional external relay or contactor.
Caution!
The C1/C2 contact is a 24 V low-voltage con-
tact and should never be used as a 230 V
switching contact.