20 Installation Manual auroMATIC 560
6 Start-up
6.1 Setting the system parameters
Certain system parameters have to be set in order to
optimise the system for the respective conditions. These
parameters are all together on one operating level and
should only be set by the heating engineer.
You can access this operating level by pressing the pro-
gramming button “P” for approx. 3 seconds.
Display Turn the dial to adjust Setting range Factory setting
Changing the hydraulic plan 1, 2, 3 1
Setting the flow rate
When setting the the required flow rate,
please observe the measurement units used
for the flow rate limiter installed!
0 – 9990 l/h 0
Resetting the solar yield.
The solar yield is reset to 0 by turning the
dial to 1.
--
Resetting the operating hours.
The operating hours are reset to 0 by turning
the dial to 1.
--
Setting the max. temperature for cylinder 1 20 to 80 °C 75 °C
Setting the activation difference for cylinder 1
(The activation difference should always be 2
K greater than the deactivation difference)
5 – 12 K 7 K
Setting the deactivation difference for cylin-
der 1
(The deactivation difference should always be
2 K less than the activation difference)
1 – 10 K 3 K
Table 6.1 System parameters
Then you can call up all of the system parameters suc-
cessively by clicking the dial. You can adjust the values
you want by turning the dial. The adjusted value is saved
with one click.
When you press the P button, the display returns to
basic operating level without saving the adjusted value.
The following table gives an overview of all system
parameters and their factory settings: