40 Instructions for installation and servicing ecoTEC 839592_12
Release water from the system until the system design
pressure of 1.0 bar is attained. (The actual reading on the
digital pressure gauge should ideally be 0.5 bar plus an
additional pressure corresponding to the highest point of
the system above the base of the boiler – 10 m head equals
an additional 1 bar reading on the pressure gauge. The
minimum pressure should not be less than 1 bar in any
installation.) If the system is to be treated with an inhibitor it
should be applied at this stage in accordance with the
manufacturer’s instructions.
Further information can be obtained from Sentinel,
Betz Dearborn Ltd., Tel: 0151 420 9595, or Fernox,
Alpha–Fry technologies. Tel: 0870 8700362.
Refit the boiler casing (see section 5.10).
• Only in ecoTEC plus appliances: Attach the bottom cover
to the boiler by sliding the front edge of the cover into
the lip at the bottom front edge of the appliance chassis.
Carefully push the rear of the bottom cover upwards
until the spring retaining clips engage at the side of
the appliance. It may be necessary to adapt the bot-
tom cover by removing the easy break sections.
6.2 Handing over to the user
Note
When you have finished the installation, attach
the sticker supplied (835593) to the appliance
in the user’s language.
Set the maximum radiator temperature control to the
desired setting.
Set the maximum hot water temperature control to
the desired setting.
Instruct the user in the safe and efficient operation of
the boiler, in particular the function of
the boiler on/off control
the maximum radiator temperature control
the maximum hot water temperature control
(combination boilers only)
– the pressure gauge.
Show the user how to operate any external controls.
• Explain to the user the importance of having the boiler
regularly serviced by a competent servicing company.
To ensure regular servicing, it is strongly
recommended that arrangements are made for a
Maintenance Agreement. Contact Vaillant Service
Solutions (0870 6060 777) for further details.
Record central heating operating pressure in the
Benchmark gas boiler commissioning checklist along
with the heat input (kW) and temperature difference
between flow and return.
Leave the user instructions and the installation
instructions with the user.
Go through the operating manual with the user and
answer any questions.
Draw special attention to the safety instructions,
which the user must follow.
Instruct the user about the methods used for
combustion air supply and flue conducting. In
particular, point out that these measures must not be
altered.
Inform the user that the instruction manuals should
be kept near the appliance.
6.3 Factory guarantee
Two year guarantee for ecoTEC plus appliances
Vaillant undertakes to rectify any manufacturing defect
that occurs within twenty-four months of the installation
date.
For the 2nd year of the guarantee to be valid an annual
service must be carried out by a competent person
approved at the time by the Health and Safety
Executive one year after installation.
The cost of this annual service is not included in the
guarantee.
One year guarantee for ecoTEC pro appliances
Vaillant undertakes to rectify any manufacturing defect
that occurs within twelve months of the installation
date.
Registering with us
Registration is simple. Just complete the Guarantee
Registration Card and return to Vaillant within 30 days
of installation. Your details will then be automatically
registered within the Vaillant scheme.
Note: No receipt will be issued.
Immediate help
If your Vaillant boiler develops a fault your first action
should be to contact your installer, as his professional
assessment is needed under the terms of our
Guarantee.
If you are unable to contact your installer, phone
Vaillant Service Solutions: 0870 6060 777.